EU-PCM-FS is a thixotropic thermal phase change material, wax-based self-supporting.
At temperature greater than 52°C, EU-PCM-FS changes into a molten state creating a very thin low thermal resistance interface, between heat sink and component surfaces.
EU-PCM-FS is thixotropic and doesn’t flow from the interfaces. EU-PCM-FS has a thickness of 0,125mm and available with or without adhesive depending on the mounting requirements of the application.
– Very low thermal resistance
– High reliability
– Easy to use and handling
– UL94 V0
| Colour | White |
| Construction | Thixotropic non-reinforced film |
| Thickness | 0,127 mm |
| Density | 2,0 g/cc |
| Temperature range | -60 °C to 200 °C |
| Approximate thermal resistance (°C·in²/W) | 0,03°C-in² / watt @ 20 psi |
| Phase Change Softening Range | 52 °C |
| Volumic resistivity | 10^14 Ohm-cm |
| Dielectric constant @ 1 MHz | – |
The Thermal phase change material – EU-PCM-FS are available in a range of variants designed to meet specific application needs. These versions differ in format, construction, or additional features, providing flexibility in design and optimal compatibility with various systems and assembly processes.
Interested in learning more about how the Thermal phase change material – EU-PCM-FS can support your project or application? Whether you need technical details, pricing information, or would like to request a sample, our team is here to help. Fill out the form below and we’ll get back to you with the support and solutions you need. Discover how the Thermal phase change material – EU-PCM-FS can bring added value to your design and performance requirements.
"*" indica i campi obbligatori
The information and technical data provided on this website are for general informational purposes only. While we strive to ensure that all content is accurate, complete, and up to date, we make no representations or warranties of any kind, express or implied, regarding the reliability, suitability, or availability of the information contained herein.
Any reliance you place on such information is strictly at your own risk. We disclaim any liability for errors, inaccuracies, or omissions and for any loss, injury, or damages resulting from the use of the information provided.
Technical specifications, data, or figures may be subject to change without notice. For official, detailed, or binding information, please contact us directly.